-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2012.0992 ICSA-12-283-01 SIEMENS S7-1200 WEB APPLICATION CROSS-SITE SCRIPTING VULNERABILITY 16 October 2012 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SIMATIC S7-1200 Publisher: US-CERT Operating System: Network Appliance Impact/Access: Cross-site Scripting -- Remote with User Interaction Resolution: Patch/Upgrade CVE Names: CVE-2012-3040 Original Bulletin: http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf - --------------------------BEGIN INCLUDED TEXT-------------------- ICS-CERT ADVISORY ICSA-12-283-01 SIEMENS S7-1200 WEB APPLICATION CROSS-SITE SCRIPTING VULNERABILITY October 9, 2012 OVERVIEW This advisory provides mitigation details provided by Siemens for a vulnerability that impacts the Siemens S7-1200 Web Application Module. Siemens has reported [a] a cross-site scripting (XSS) vulnerability in Siemens's S7-1200 Programmable Logic Controllers (PLCs). Positive Technologies [b] discovered this vulnerability and reported it directly to Siemens. Siemens has provided mitigations and a firmware update to fix this vulnerability. Exploitation of this vulnerability would allow an attacker to partially modify application data and limit the availability of the device. This vulnerability affects the electric, critical manufacturing, chemical, and food and beverage sectors. This vulnerability can be exploited remotely. AFFECTED PRODUCTS Siemens reports that the vulnerabilities affect the following versions of S7-1200 PLCs: * V2.x, * V3.0.0, and * V3.0.1. IMPACT An attacker that successfully exploits this vulnerability can run malicious JavaScript code on the target machine. Malicious code can execute various actions such as modify browser contents delivered from the PLC, steal session data, and issue commands from the PLCs Web server. Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. BACKGROUND Products in the Siemens SIMATIC S7-1200 PLC family have been designed for process control in industrial environments such as manufacturing, power generation and distribution, food and beverages, and chemical industries worldwide. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW CROSS-SITE SCRIPTING [c] The Web application does not filter user input in a way that prevents cross-site scripting. If a user is enticed into passing specially crafted, malicious input to the S7-1200 Web application via an HTTP request (e.g., by clicking on a malicious URL with embedded JavaScript), JavaScript code can be returned and may then be executed by the users browser. Various actions could be triggered by running malicious JavaScript code, including modification of browser content delivered from the PLC; stealing data, such as session cookies; issuing commands in the guise of the user to the PLCs Web server. CVE-2012-3040 [d] has been assigned to this vulnerability. A CVSS v2 base score of 8.3 has been assigned; the CVSS vector string is (AV:N/AC:M/Au:N/C:P/I:P/A:C). [e] VULNERABILITY DETAILS EXPLOITABILITY This vulnerability could be exploited remotely. EXISTENCE OF EXPLOIT No known public exploits specifically target this vulnerability. DIFFICULTY An attacker with medium skill level would be able to exploit this vulnerability. MITIGATION Siemens has released a security advisory [f] that details this vulnerability. It recommends users obtain the new updated firmware for Versions 3.0.0 and 3.0.1 of the S7-1200 by contacting Technical Support in their region: * Germany: +49 (0) 911 895 7222 * Americas: +1 423 262 5710 * Asia-Pacific: +86 10 6475 7575 Siemens also advises users who are unable to apply this firmware update to use the following mitigations. * Disable JavaScript within the Web browser used to access the S7-1200 Web server. * Utilize a modern Web browser with integrated XSS filtering mechanisms. * Deactivate the S7-1200 Web server wherever possible. For this version of firmware (3.0.2), Siemens has also removed the HTTP PUT functionality, because it is not used by the S7-1200 Web server. ICS-CERT encourages asset owners to take additional defensive measures to protect against this and other cybersecurity risks. * Minimize network exposure for all control system devices. Critical devices should not directly face the Internet. * Locate control system networks and remote devices behind firewalls, and isolate them from the business network. * When remote access is required, use secure methods, such as Virtual Private Networks(VPNs), recognizing that VPN is only as secure as the connected devices. ICS-CERT also provides a section for control systems security recommended practices on the US-CERT Web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. [g] ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to taking defensive measures. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01A - Cyber Intrusion Mitigation Strategies, [h] that is available for download from the ICS-CERT Web page (www.ics-cert.org). Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks. 1. Do not click Web links or open unsolicited attachments in email messages. 2. Refer to Recognizing and Avoiding Email Scams [i] for more information on avoiding email scams. 3. Refer to Avoiding Social Engineering and Phishing Attacks [j] for more information on social engineering attacks. ICS-CERT CONTACT For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@dhs.gov Toll Free: 1-877-776-7585 For industrial control systems security information and incident reporting: www.ics-cert.org ICS-CERT continuously strives to improve its products and services. You can help by answering a short series of questions about this product at the following URL: https://forms.uscert.gov/ncsd-feedback/. DOCUMENT FAQ What is an ICS-CERT Advisory? An ICS-CERT Advisory is intended to provide awareness or solicit feedback from critical infrastructure owners and operators concerning ongoing cyber events or activity with the potential to impact critical infrastructure computing networks. When is vulnerability attribution provided to researchers? Attribution for vulnerability discovery is always provided to the vulnerability reporter unless the reporter notifies ICS-CERT that they wish to remain anonymous. ICS-CERT encourages researchers to coordinate vulnerability details before public release. The public release of vulnerability details prior to the development of proper mitigations may put industrial control systems and the public at avoidable risk. REFERENCES a. SSA-279823, http://www.siemens.com/corporate-technology/en/research-areas/siemens-cert-security-advisories.htm Web site last accessed October 9, 2012. b. Positive Technologies, http://ptsecurity.com/, Web site last accessed October 9, 2012. c. CWE-79: Improper Neutralization of Input During Web Page Generation, http://cwe.mitre.org/data/definitions/79.html, Web site last accessed October 9, 2012. d. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2012-3040, NIST uses this advisory to create the CVE Web site report. This Web site will be active sometime after publication of this advisory. e. CVSS Calculator, http://nvd.nist.gov/cvss.cfm?version=2&vector=(AV:N/AC:M/Au:N/C:P/I:P/A:C), Web site last accessed October 9, 2012. f. Siemens Security Advisory, http://www.siemens.com/corporatetechnology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf Website last accessed October 9, 2012. g. CSSP Recommended Practices, http://www.us-cert.gov/control_systems/practices/Recommended_Practices.html, Web site last accessed October 9, 2012. h. Cyber Intrusion Mitigation Strategies, http://www.us-cert.gov/control_systems/pdf/ICS-TIP-12-146-01A.pdf, Web site last accessed October 9, 2012. i. Recognizing and Avoiding Email Scams, http://www.us-cert.gov/reading_room/emailscams_0905.pdf, Web site last accessed October 9, 2012. j. National Cyber Alert System Cyber Security Tip ST04-014, http://www.us-cert.gov/cas/tips/ST04-014.html, Web site last accessed October 9, 2012. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBUHzCA+4yVqjM2NGpAQIFShAAlQIJ9+YUny1ENLGBaWo5MRTj7dzaAO5A uTyiO9jgd4pE6q3sx2VngTbP331Mm3Kuj1sedxjodV2cwfl0Gih1cpXZPbHbvrBG z69Kr1eBlJRcp8V4lJhMxVKnRvhI8QZxpuJcECuosn5iwW1b12ASDdGgdhZ9MGfT RxiDIUpSgAWV8lazytu2lBPb+z1oAchHA8IS4g9PZgA/OnulyKbul3zAL/AHDhlQ pmyKZp3Ks0ISph+zRNgzkMxo5ynd4Vw5I7srpwWVexqEkRSsK+KuIYLDeKRINHRR 9ReTQ30OicoYdbeATp9YWLgEEQ88rTTalpA7zcFrnldQ+lt8mwSTpIxaSf0FeMIk jh4vi+e7pjFkuLJGgiOUSU5pHWo0krB6WsgSV5h22Vc5yuZ4d4OJ06npBcvVl9y6 jCx+UzRNXSoctrmMDqoBJtGNZJoPomXi+nV/uor0ob3oFPhRl5YVjCrrZyC4HvlE nTO09DgBtmX8adiEwYNXJXbO4IId+x5+u0XgwP73GAWkcqgZNwwPJejUvzwlNpB7 +qul4GiiQMZj0Rr/N3fugO3WBgBjEUHC4qDdj83kjVv5wklLMBLXF4O0Lt8j8cvu 66cA4Xpl25yhYTX+iudxrr+1k8EUpkFeoDY6nD3L8YDQaMTI77/ZRGoJLOUNbMEI 6M4MXKrPAuA= =IZT2 -----END PGP SIGNATURE-----