Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2016.2033 Moxa OnCell Vulnerabilities 24 August 2016 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Moxa OnCell Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Access Privileged Data -- Existing Account Reduced Security -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2016-5812 CVE-2016-5799 Original Bulletin: http://ics-cert.us-cert.gov/advisories/ICSA-16-236-01 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-16-236-01) Moxa OnCell Vulnerabilities Original release date: August 23, 2016 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. OVERVIEW Independent researcher Maxim Rupp has identified several vulnerabilities in Moxas OnCell products. Moxa has produced new firmware to mitigate these vulnerabilities. These vulnerabilities could be exploited remotely. AFFECTED PRODUCTS Moxa reports that the vulnerability affects the following products: OnCell G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 IMPACT An attacker could exploit these vulnerabilities to bypass authentication to log in as a valid user. Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. BACKGROUND Moxa is a Taiwan-based company that maintains offices in several countries around the world, including the US, UK, India, Germany, France, China, Russia, and Brazil. The affected products, OnCell 31XX and 32XX series devices, are cellular IP gateways that can connect serial or Ethernet devices to a cellular network. According to Moxa, OnCell IP gateways are deployed across several sectors including Commercial Facilities, Critical Manufacturing, Energy, and Transportation Systems. Moxa estimates that these products are used primarily in Asia and Europe. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW IMPROPER RESTRICTION OF EXCESSIVE AUTHENTICATION ATTEMPTS [a] An attacker can freely use brute force to determine parameters needed to bypass authentication. CVE-2016-5799 [b] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). [c] PLAINTEXT STORAGE OF A PASSWORD [d] A configuration file contains parameters that represent passwords in plaintext. CVE-2016-5812 [e] has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N). [f] VULNERABILITY DETAILS EXPLOITABILITY These vulnerabilities could be exploited remotely. EXISTENCE OF EXPLOIT No known public exploits specifically target these vulnerabilities. DIFFICULTY An attacker with a low skill would be able to exploit these vulnerabilities. MITIGATION Moxa has made firmware fixes available on their web site at the following locations: http://www.moxa.com/support/sarch_result.aspx?type=soft&prod_id=316&type_id=4 (link is external) http://www.moxa.com/support/sarch_result.aspx?type=soft&prod_id=416&type_id=4 (link is external) Moxa offers the following advice for upgrading firmware: The OnCell G3111/G3151-HSPAs firmware can be upgraded though the web console, serial console, or through OnCell Search Utility. However, Moxa recommends a local (LAN) connection to the OnCell to minimize the risk of a broken connection during the upgrade process. If you have made any changes to your configuration, remember to save the configuration first before upgrading the firmware. Any unsaved changes will be discarded when the firmware is upgraded. To upgrade the firmware, simply browse to the location of the firmware on your PC, and select Submit. ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at: http://ics-cert.us-cert.gov/content/recommended-practices. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the ICSCERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/). Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. a. CWE-307: Improper Restriction of Excessive Authentication Attempts, http://cwe.mitre.org/data/definitions/307.html, web site last accessed August 23, 2016. b. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-5799, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. c. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed August 23, 2016. d. CWE-256: Plaintext Storage of a Password, http://cwe.mitre.org/data/definitions/256.html, web site last accessed August 23, 2016. e. NVD, http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-5812, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. f. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S..., web site last accessed August 23, 2016. Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov (link sends e-mail) Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBV70jpIx+lLeg9Ub1AQgrMQ//de3GzP9u5Nv0ouJo3+VfUAe6QobMPA7L o2DRt4DNngx2BElXR5Ah2IR4wJHVDPF2ja5i7NR2FM72PRTBqjExYAGHcXPAwvHO kRmTqvmE4AVtlMRoxQOpu7h1gUWqnAh9md3onIB/31Of2+VbI1F4LMLAtxaVemR8 lGY4i8+TcKbGt4Ljun108Z2Jw3ueonWOUgGoravo1ajU/rTnvHICkpXI7K8fcVeb SEadVU+otGZ93GFgcamtwpJifEO1DXPRT/axhI5EELCQSxl2qARZV5uqokS8sryc YapqRv/q2QfyHRohgdkt+E/YTGb4nhGI4itd34/LDPQYaZVSfvYTP78SDfA1wLk6 xEBEqwBnBJgLzXydwyQCjwJUwTy54QZhuLPzj39F5WO9M6DVgyxxjtcJUe7VcB8C 6SjTGEKtbZbp4xx4XfzKdQXHSk75ympmnrh0XLQUp/ipdgg4jPOvNXbUKPjPKjVx LH/D5qSXMww+SPcv20nF/93MYRLPNPc2hKBB7jCLYevOWm3ocoO/MMH0//E5kK6U 0mbZiV5q9Bzz9lMK5SfK9L2JhRTFviFKnDMlgdK9gVkf/zDp5YwGm0Toyjo5wk/o CGMs47/N1Wq4zW+fIMLySAaebchiRJvKzUOt1CV4kpicJV+nzp0zkthT9jzIAQPx UoC2OckCCa4= =dqUh -----END PGP SIGNATURE-----