-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA256

===========================================================================
             AUSCERT External Security Bulletin Redistribution

                               ESB-2016.2548
  DoS Vulnerability in Hitachi Command Suite and JP1/Automatic Operation
                              31 October 2016

===========================================================================

        AusCERT Security Bulletin Summary
        ---------------------------------

Product:           Hitachi Command Suite
Publisher:         Hitachi
Operating System:  Windows
                   Linux variants
                   Solaris
Impact/Access:     Denial of Service -- Remote/Unauthenticated
Resolution:        Patch/Upgrade
CVE Names:         CVE-2016-3092  

Reference:         ESB-2016.2544
                   ESB-2016.2516
                   ESB-2016.2488
                   ESB-2016.2433
                   ESB-2016.2432

Original Bulletin: 
   http://www.hitachi.co.jp/Prod/comp/soft1/global/security/info/vuls/HS16-026/index.html

- --------------------------BEGIN INCLUDED TEXT--------------------

DoS Vulnerability in Hitachi Command Suite and JP1/Automatic Operation

Security Information ID: hitachi-sec-2016-126

Update: October 31, 2016

A vulnerability to denial-of-service attacks (CVE-2016-3092) was found in Hitachi Command Suite and JP1/Automatic Operation.

Vulnerability ID
HS16-026

Vulnerability description
A vulnerability to denial-of-service attacks (CVE-2016-3092) was found in Hitachi Command Suite and JP1/Automatic Operation.
Affected products and versions are listed below. Please upgrade your version to the appropriate version, or apply the Workarounds.

Affected products
The information is organized under the following headings:
(Example)
Product name: Gives the name of the affected product.

  Version:

  Platform
    Gives the affected version.


Product name: Hitachi Device Manager

  Version(s):

  Windows, Linux
  7.0.0-00 or more and less than 8.4.1-03

  Solaris
  7.0.0-00 or more and less than 8.0.0-00

Product name: Hitachi Tiered Storage Manager

  Version(s):

  Windows, Linux
  7.0.0-00 or more and less than 8.4.1-03

  Solaris
  7.0.0-00 or more and less than 8.0.0-00

Product name: Hitachi Compute Systems Manager (Japanese version)

  Version(s):

  Windows
  7.4.1-02 or more and less than 8.4.1-03

Product name: Hitachi Compute Systems Manager (English version)

  Version(s):

  Windows, Linux
  7.2.0-00 or more and less than 8.4.1-03

Product name: Hitachi Automation Director

  Version(s):

  Windows
  8.1.1-00 or more and less than 8.4.1-03

  Linux
  8.2.1-00 or more and less than 8.4.1-03

Product name: Hitachi Global Link Manager

  Version(s):

  Windows
  5.0.0-00 or more and less than 8.4.1-02

Product name: Hitachi Tuning Manager

  Version(s):

  Windows
  3.5.0-00 or more and less than 8.5.0-00

  Linux
  7.1.0-00 or more and less than 8.5.0-00

  Solaris
  3.5.0-00 or more and less than 8.0.0-00

Product name: Hitachi Infrastructure Analytics Advisor

  Version(s):

  Windows
  2.0.0-00 or more and less than 2.1.0-00

Product name: JP1/Automatic Operation

  Version(s):

  Windows
  10-00 or more and less than 11-00-03

  Linux
  10-52 or more and less than 11-00-03

Product name: Job Management Partner 1/Automatic Operation

  Version(s):

  Windows
  10-00 to 10-50

Fixed products

The information is organized under the following headings:
(Example)
Product name: Gives the name of the fixed product.

  Version:
  Platform
    Gives the fixed version, and release date.

  Scheduled version:
  Platform
    Gives the fixed version scheduled to be released.

Product name: Hitachi Device Manager

  Version(s):

  Windows, Linux
  8.4.1-03 August 1, 2016

Product name: Hitachi Tiered Storage Manager

  Version(s):

  Windows, Linux
  8.4.1-03 August 1, 2016

Product name: Hitachi Compute Systems Manager (Japanese version)

  Version(s):

  Windows
  8.4.1-03 August 1, 2016

Product name: Hitachi Compute Systems Manager (English version)

  Version(s):

  Windows, Linux
  8.4.1-03 August 1, 2016

Product name: Hitachi Automation Director

  Version(s):

  Windows, Linux
  8.4.1-03 August 1, 2016

Product name: Hitachi Global Link Manager

  Version(s):

  Windows
  8.4.1-02 August 8, 2016

Product name: Hitachi Tuning Manager

  Version(s):

  Windows, Linux
  8.5.0-00 October 26, 2016

Product name: Hitachi Infrastructure Analytics Advisor

  Version(s):

  Windows
  2.1.0-00 October 17, 2016

Product name: JP1/Automatic Operation

  Version(s):

  Windows, Linux
  11-00-03 August 4, 2016

For details on the fixed products, contact your Hitachi support service representative.

Workarounds
For details about the workarounds, contact your Hitachi support service representative.

Revision history
October 31, 2016    This page is released.

- --------------------------END INCLUDED TEXT--------------------

You have received this e-mail bulletin as a result of your organisation's
registration with AusCERT. The mailing list you are subscribed to is
maintained within your organisation, so if you do not wish to continue
receiving these bulletins you should contact your local IT manager. If
you do not know who that is, please send an email to auscert@auscert.org.au
and we will forward your request to the appropriate person.

NOTE: Third Party Rights
This security bulletin is provided as a service to AusCERT's members.  As
AusCERT did not write the document quoted above, AusCERT has had no control
over its content. The decision to follow or act on information or advice
contained in this security bulletin is the responsibility of each user or
organisation, and should be considered in accordance with your organisation's
site policies and procedures. AusCERT takes no responsibility for consequences
which may arise from following or acting on information or advice contained in
this security bulletin.

NOTE: This is only the original release of the security bulletin.  It may
not be updated when updates to the original are made.  If downloading at
a later date, it is recommended that the bulletin is retrieved directly
from the author's website to ensure that the information is still current.

Contact information for the authors of the original document is included
in the Security Bulletin above.  If you have any questions or need further
information, please contact them directly.

Previous advisories and external security bulletins can be retrieved from:

        http://www.auscert.org.au/render.html?cid=1980

===========================================================================
Australian Computer Emergency Response Team
The University of Queensland
Brisbane
Qld 4072

Internet Email: auscert@auscert.org.au
Facsimile:      (07) 3365 7031
Telephone:      (07) 3365 4417 (International: +61 7 3365 4417)
                AusCERT personnel answer during Queensland business hours
                which are GMT+10:00 (AEST).
                On call after hours for member emergencies only.
===========================================================================
-----BEGIN PGP SIGNATURE-----
Comment: http://www.auscert.org.au/render.html?it=1967
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=/bdY
-----END PGP SIGNATURE-----