Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2016.2757 Vanderbilt Industries Siemens IP CCTV Cameras Vulnerability 21 November 2016 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens IP CCTV Cameras Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Access Privileged Data -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2016-9155 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-16-322-01 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-16-322-01) Vanderbilt Industries Siemens IP CCTV Cameras Vulnerability Original release date: November 17, 2016 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. OVERVIEW Siemens reports that there is a vulnerability in Siemens-branded IP cameras from Vanderbilt Industries. Vanderbilt has released updates to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following versions of Siemens-branded IP cameras built by Vanderbilt Industries: CCMW3025: All versions prior to 1.41_SP18_S1, CVMW3025-IR: All versions prior to 1.41_SP18_S1, CFMW3025: All versions prior to 1.41_SP18_S1, CCPW3025: All versions prior to 0.1.73_S1, CCPW5025: All versions prior to 0.1.73_S1, CCMD3025-DN18: All versions prior to v1.394_S1, CCID1445-DN18: All versions prior to v2635, CCID1445-DN28: All versions prior to v2635, CCID1445-DN36: All versions prior to v2635, CFIS1425: All versions prior to v2635, CCIS1425: All versions prior to v2635, CFMS2025: All versions prior to v2635, CCMS2025: All versions prior to v2635, CVMS2025-IR: All versions prior to v2635, CFMW1025: All versions prior to v2635, and CCMW1025: All versions prior to v2635. IMPACT A successful exploit of this vulnerability may allow the attacker to obtain administrative credentials. Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. BACKGROUND Vanderbilt Industries acquired the SIEMENS IP Cameras business in June 2015 and released updates for the affected camera models under the SIEMENS brand. The SIEMENS-branded IP-based CCTV cameras portfolio includes a range of megapixel cameras in various configuration and mounting options. According to Vanderbilt, these products are deployed across several sectors including Commercial Facilities, Healthcare and Public Health, and Government Facilities. Vanderbilt estimates that these products are used worldwide. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW INSUFFICIENTLY PROTECTED CREDENTIALS[a] An attacker with network access to the web server could obtain administrative credentials by sending certain requests. CVE-2016-9155[b] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).[c] VULNERABILITY DETAILS EXPLOITABILITY This vulnerability could be exploited remotely. EXISTENCE OF EXPLOIT No known public exploits specifically target this vulnerability. DIFFICULTY An attacker with a low skill would be able to exploit this vulnerability. MITIGATION Vanderbilt has released updates to mitigate this vulnerability. For links to the new versions for each of the affected models, please see Siemens Security Advisory SSA-284765 at the following location: http://www.siemens.com/cert/advisories (link is external) Siemens recommends that users operate the devices within trusted networks and protect network access to the devices with appropriate mechanisms. Siemens also recommends enabling authentication on the web server. ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. a. CWE-522: Insufficiently Protected Credentials, https://cwe.mitre.org/data/definitions/522.html, web site last accessed November 17, 2016. b. NVD, https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9155, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. c. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed November 17, 2016. Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov (link sends e-mail) Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBWDI9CYx+lLeg9Ub1AQh05A//Ykq9PSoSOSnmVgXIJ5zAdakZ4h3eDKgv qOaTN0BwYgC5wV9PWBzKAlCUFfj4NRfFjPvQBnsvoC/aThxL1SXfe7FRjjjVAlli oG2XFPnl7fPW95EEGfYwSVX3stCmDGKyPJX/WGyJGSPgaVWm1x2mm9t+4YVfwgCo jQBEOfY/4hZKCXPTE3DjA+0p6IC3d+ZxbD5/Rl1DAF+DkeWguOZ4NjfqF1eOhwRM axMMiMPVxhqOB4RlTvzqlVf7XUV7YxNEBHj6WZ8dsGdQlb338mJj5lWdIxPv9ml9 L7nKUkul1K1wDVcBoJN8bB9S76Rb/yFKxjgWSmS+be8TEKWBAqiEWeNS8IAIV8pI zc0ULqcauJJPIxKpJ4Xmjinq43RAy0gNWgvwozJcyWFyHRqKrYKRLnRM0vpR3Dgj eI8RUq0DcBwiPBosR+ZSbMffAP/VnwuxfM0hnqwAQjp/VGiampsDcH1Y4tckXT4f SgDGCw4x63N30KYTSTqFBtLVDwpKqP/GhE1cwkBAzkwPkly0zhdS10wKgdxEEeHl IAId0SDm+e6KeaM9zbUvnb8e1T/pSlb6SIO2GnfvYLABDgtvSZ8Zrwphegj+SMHw sXPTul/cmmSR6IKK2AmcxQpxsRNTp6uBVLR9sgWl8nLrzJAylJlgRmqVtKvOO/BY hZYyQXNEEDc= =ppko -----END PGP SIGNATURE-----