Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2017.0061 Rockwell Automation Logix5000 Programmable Automation Controller Buffer Overflow Vulnerability 9 January 2017 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Rockwell Automation Logix5000 Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2016-9343 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-16-343-05) Rockwell Automation Logix5000 Programmable Automation Controller Buffer Overflow Vulnerability Original release date: January 05, 2017 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. OVERVIEW This advisory was originally posted to the NCCIC Portal library on December 8, 2016, and is being released to the NCCIC/ICS-CERT web site. Rockwell Automation has identified a buffer overflow vulnerability in Rockwell Automation's Logix5000 Programmable Automation Controller product line. Rockwell Automation has produced new firmware versions to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following firmware versions for the Logix5000 Controller product line are affected, excluding all firmware versions prior to FRN 16.00, which are not affected: FRN 16.00 ControlLogix 5560 controllers (V16.020 through V16.022), ControlLogix L55 controllers (V16.020 through V16.022), ControlLogix 5560 Redundant controllers (all versions ), GuardLogix 5560 controllers (all versions), FlexLogix L34 controllers (all versions), 1769 CompactLogix L23x controllers (all versions), 1769 CompactLogix L3x controllers (V16.020 through V16.023), and 1768 CompactLogix L4x controllers, (V16.020 through V16.025). FRN 17.00 SoftLogix 5800 controllers (all versions), ControlLogix 5560 controllers (all versions), GuardLogix 5560 controllers (all versions), 1769 CompactLogix L23x controllers (all versions), 1769 CompactLogix L3x controllers (all versions), and 1768 CompactLogix L4x controllers (all versions). FRN 18.00 SoftLogix 5800 controllers (all versions), RSLogix Emulate 5000 (all versions), ControlLogix 5560 controllers (all versions), ControlLogix 5570 controllers (all versions), GuardLogix 5560 controllers (all versions), 1769 CompactLogix L23x controllers (all versions), 1769 CompactLogix L3x controllers (all versions), 1768 CompactLogix L4x controllers (all versions) , and 1768 Compact GuardLogix L4xS (all versions). FRN 19.00 SoftLogix 5800 controllers (all versions), RSLogix Emulate 5000 (all versions), ControlLogix 5560 controllers (all versions), ControlLogix 5570 controllers (all versions), ControlLogix 5560 Redundant controllers (all versions), GuardLogix 5560 controllers (all versions), 1769 CompactLogix L23x controllers (all versions), 1769 CompactLogix L3x controllers (all versions), 1768 CompactLogix L4x controllers (all versions), and 1768 Compact GuardLogix L4xS controllers (all versions). FRN 20.00 SoftLogix 5800 controllers (all versions), RSLogix Emulate 5000 (all versions), ControlLogix 5560 controllers (V20.010 through V20.013), ControlLogix 5570 controllers (V20.010 through V20.013), ControlLogix 5560 Redundant controllers (V20.050 through V20.055), ControlLogix 5570 Redundant controllers (V20.050 through V20.055), GuardLogix 5560 controllers (V20.010 through V20.017), GuardLogix 5570 controllers (V20.010 through V20.017), 1769 CompactLogix L23x controllers (V20.010 through V20.013), 1769 CompactLogix L3x controllers (V20.010 through V20.013), 1769 CompactLogix 5370 L1 controllers (V20.010 through V20.013), 1769 CompactLogix 5370 L2 controllers (V20.010 through V20.013), 1769 CompactLogix 5370 L3 controllers (V20.010 through V20.013), 1768 CompactLogix L4x controllers (V20.011 through V20.016), and 1768 Compact GuardLogix L4xS controllers (V20.011 through V20.013). FRN 21.00 SoftLogix 5800 controllers (all versions), RSLogix Emulate 5000 (all versions), ControlLogix 5570 controllers (all versions), ControlLogix 5570 Redundant controllers (all versions), GuardLogix 5570 controllers (all versions), 1769 CompactLogix 5370 L1 controllers (all versions), 1769 CompactLogix 5370 L2 controllers (all versions), and 1769 CompactLogix 5370 L3 controllers (all versions). IMPACT Successful exploitation of this vulnerability may allow a remote attacker to cause a denial of service at a controller or execute code on a target controller. Impact to individual organizations depends on many factors that are unique to each organization. ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. BACKGROUND Rockwell Automation, which is a US-based company, provides industrial automation control and information products worldwide across a wide range of industries. The affected products in the Logix5000 Controller product line are PLCs. According to Rockwell Automation, the Logix5000 Controllers are deployed across several sectors including Critical Manufacturing, Food and Agriculture Sector, Water and Wastewater Systems, and others. Rockwell Automation estimates that these products are used worldwide. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW STACK-BASED BUFFER OVERFLOW[a] By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service. CVE-2016-9343[b] has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).[c] VULNERABILITY DETAILS EXPLOITABILITY This vulnerability could be exploited remotely. EXISTENCE OF EXPLOIT No known public exploits specifically target this vulnerability. DIFFICULTY An attacker with low skill would be able to exploit this vulnerability. MITIGATION Rockwell Automation has released new firmware versions to mitigate the identified vulnerability in the affected Logix5000 Controllers, with the exception of the FlexLogix controller, which has been discontinued and no longer supported. Rockwell Automation encourages users to install the new firmware versions, which are as follows: SoftLogix 5800, FRN 23 (Catalog Number: 1789-Lx), the product fix is incorporated into FRN 23.00 and above; RSLogix Emulate 5000, FRN 23 (Catalog Number: 9310-Wx), the product fix is incorporated into FRN 23.00 and above; ControlLogix L55, FRN 16 (Catalog Number: 1756-L55x), the product fix is incorporated into FRN 16.023 and above; ControlLogix 5560, FRN 16 (Catalog Number: 1756-L6), the product fix is incorporated into FRN 16.023 and above; ControlLogix 5560, FRN 20 (Catalog Number: 1756-L6), the product fix is incorporated into FRN 20.014 and above; ControlLogix 5570, FRN 20 (Catalog Number: 1756-L7), the product fix is incorporated into FRN 20.014 and above; ControlLogix 5570, FRN 23 (Catalog Number: 1756-L7), the product fix is incorporated into FRN 23.012 and above; ControlLogix 5570, FRN 24 (Catalog Number: 1756-L7), the product fix is incorporated into FRN 24 and above; ControlLogix 5560 Redundant, FRN 20 (Catalog Number: 1756-L6), the product fix is incorporated into FRN 20.056 and above; ControlLogix 5570 Redundant, FRN 20 (Catalog Number: 1756-L7), the product fix is incorporated into FRN 20.056 and above; ControlLogix 5570 Redundant, FRN 24 (Catalog Number: 1756-L7), the product fix is incorporated into FRN 24.052 and above; ControlLogix L23x and L3x, FRN 20 (Catalog Number: 1769-L23, 1769-L31, 1769-L32, 1769-L35), the product fix is incorporated into FRN 20.014 and above; 1769 CompactLogix 5370 L1, L2, and L3 Controllers, FRN 20 (Catalog Numbers: 1769-L1, 1769-L2, and 1769-L3), the product fix is incorporated into FRN 20.014 and above; 1769 CompactLogix 5370 L1, L2, and L3 Controllers, FRN 23 (Catalog Numbers: 1769-L1, 1769-L2, and 1769-L3), the product fix is incorporated into FRN 23.012 and above; 1769 CompactLogix 5370 L1, L2, and L3 Controllers, FRN 24 (Catalog Numbers: 1769-L1, 1769-L2, and 1769-L3), the product fix is incorporated into FRN 24 and above; CompactLogix L4 Controllers, FRN 16 (Catalog Number: 1768-L4x), the product fix is incorporated into FRN 16.026 (Series A, B, and C) and FRN 16.027 and above (Series D); CompactLogix L4 Controllers, FRN 20 (Catalog Number: 1768-L4x), the product fix is incorporated into FRN 20.014 and above (Series A, B, and C) and FRN 20.016 and above (Series D); Compact GuardLogix L4xS Controllers, FRN 20 (Catalog Number: 1768-L4xS), the product fix is incorporated into FRN 20.018 and above. GuardLogix 5560, FRN 20 (Catalog Number: 1756-L6S), the product fix is incorporated into FRN 20.018 and above; ControlLogix 5570, FRN 20 (Catalog Number: 1756-L7S), the product fix is incorporated into FRN 20.018 and above; ControlLogix 5570, FRN 23 (Catalog Number: 1756-L7S), the product fix is incorporated into FRN 23.012 and above; and ControlLogix 5570, FRN 24 (Catalog Number: 1756-L7S), the product fix is incorporated into FRN 24 and above. Rockwell Automation's new firmware versions are available at the following URL: http://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx Rockwell Automation's security notification is available at the following URL, with a valid account: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/970074 Rockwell Automation recommends that users apply additional precautions and risk mitigation strategies to this type of attack, when possible, which could include the following: Use proper network infrastructure controls, such as firewalls, to help confirm that requests from unauthorized sources are blocked. Block all traffic to affected devices from outside the Manufacturing Zone by blocking or restricting access to Port 2222 TCP/UDP and Port 44818 TCP/UDP, using network infrastructure controls, such as firewalls, or other security appliances. When possible, keep the controller in RUN mode rather than Remote RUN or Remote Program in order to prevent other disruptive changes to the system. ICS-CERT recommends, as quality assurance, that users test the update in a test development environment that reflects their production environment prior to installation. In addition, users should: Minimize network exposure for all control system devices and/or systems, and help confirm that they are not accessible from the Internet. Locate control system networks and devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. a. CWE-121: Stack-based Buffer Overflow, https://cwe.mitre.org/data/definitions/121.html, web site last accessed January 05, 2017. b. NVD, https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-9343, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. c. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed January 05, 2017. Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBWHL+T4x+lLeg9Ub1AQitNBAAksjMrvh+0s+tYZu3ogtg5juS13xKj1Qw kxSleFLrTg0lQW9QJnJbJhYuJxvmePihPTwfG53zCzgCWwAJaF0bfkEEpuFt8Mso NAmaNet2JqAnw7EPeEDhZ3Pdl/3NTBi8AIKoFX7x+rygRdVF+RFpR2XdjjJZzAeC Davt2CbyzwimXhKHI1QvU36NyBS183VsqeMweaxJz+REqeR8VbUO8I0B1dAQBZi/ MEq8g5gdiPgyIGITgnmKPu4J+DWqsREGievFf1zFpWu39D18pjU4lmgMRCMZfzT7 U3ggOSD57mChAtOX680xsHA52rzaQ1AiwE0yjUMygfAy9E/RtZcoud4eaNltaqj8 +A9FTAYcTLvMjWOYEcQGCFzDGC9aTzMGg/H3J3/2wq+MexeqmKYGknU3B3v3JezJ zpZW79OyYGx7gJd4Y7+Tl6cB3StTWoNVyX81+4Fu7ZzVx0iG5oVpveY4VwaZU/FJ GYseW8lhKO2Pr/Xvqro9ocpE2CGIL2+V+eCnF056xKpWkNT56/wJOjryAdTLdPsi soy4UYFnCB0X2X2auqSIqnq5uq/7flUVgu1BcVzUpN6PWzGOmQ13cWXCSncPSZi+ eLaof5fdtXDnAapPIgqIPt3w1PegzkYmwueX8Klq23EILS/dLxhMupBkRhGeWKOg n0Hb7WHTMo8= =JSSI -----END PGP SIGNATURE-----