Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2017.1180 A vulnerability has been identified in Siemens devices using the PROFINET Discovery and Configuration Protocol 10 May 2017 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SIMATIC products Siemens SCALANCE products Siemens SIRIUS products Siemens SINAMICS products Siemens SINUMERIK products Siemens SIMOTION Siemens STEP 7 - Micro/WIN SMART Siemens SMART PC Access Siemens Primary Setup Tool (PST) Siemens Security Configuration Tool (SCT) Siemens SINEMA Server Siemens SINAUT ST7CC Siemens SITOP Publisher: ICS-CERT Operating System: Network Appliance Windows Impact/Access: Denial of Service -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2017-6865 CVE-2017-2681 CVE-2017-2680 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-17-129-01 https://ics-cert.us-cert.gov/advisories/ICSA-17-129-02 Comment: This bulletin contains two (2) ICS-CERT security advisories. - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-17-129-01) Siemens devices using the PROFINET Discovery and Configuration Protocol Original release date: May 09, 2017 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol (DCP) Vulnerability: Denial of Service AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following products using the PROFINET DCP: SIMATIC WinCC (TIA Portal) V13: All versions prior to V13 SP2, and V14: All versions prior to V14 SP1 SIMATIC STEP 7 (TIA Portal) V13: All versions prior to V13 SP2, and V14: All versions prior to V14 SP1 SIMATIC STEP 7 V5.X: All versions, STEP 7 - Micro/WIN SMART: All versions, SMART PC Access V2.0, SIMATIC Automation Tool: All versions, SIMATIC WinCC: All versions, SIMATIC PCS 7: All versions, SIMATIC NET PC-Software: All versions, Primary Setup Tool (PST): All versions, Security Configuration Tool (SCT): All versions, SINEMA Server: All versions, SINAUT ST7CC: All versions, SIMATIC WinAC RTX 2010 SP2: All versions, SIMATIC WinAC RTX F 2010 SP2: All versions, SINUMERIK 808D Programming Tool: All versions, and SIMATIC WinCC flexible 2008: All versions. IMPACT An attacker may be able to cause a denial-of-service condition requiring a manual restart by exploiting this vulnerability. MITIGATION Siemens provides updates that fix the vulnerability for the following affected products and recommends users update to the new fixed version: SIMATIC WinCC (TIA Portal) V13: Update to V13 SP2 https://support.industry.siemens.com/cs/ww/en/view/109746073 (link is external) SIMATIC WinCC (TIA Portal) V14: Update to V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109745460 (link is external) SIMATIC STEP 7 (TIA Portal) V13: Update to V13 SP2 https://support.industry.siemens.com/cs/ww/en/view/109745155 (link is external) SIMATIC STEP 7 (TIA Portal) V14: Update to V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109745984 (link is external) The affected component is shared among all of the affected products on the host. Installing one fixed version will mitigate the vulnerability for all Siemens applications installed on that host. Siemens is preparing updates for the remaining affected products and recommends the following mitigations in the meantime: Apply cell protection concept https://support.industry.siemens.com/cs/ww/en/view/60119725 (link is external) Use VPN for protecting network communication between cells Apply Defense-in-Depth As a general security measure, Siemens strongly recommends protecting industrial control systems networks with appropriate mechanisms. Siemens advises configuring the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment. https://www.siemens.com/cert/operational-guidelines-industrial-security (link is external) For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-275839 at the following location: http://www.siemens.com/cert/en/cert-security-advisories.htm (link is external) ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. VULNERABILITY OVERVIEW IMPROPER INPUT VALIDATION CWE-20 Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a denial-of-service condition in some services. The services may require manual restart to recover. CVE-2017-6865 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). RESEARCHER Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team reported this vulnerability directly to Siemens. BACKGROUND Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Chemical, Energy, Water and Wastewater Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov (link sends e-mail) Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --- Advisory (ICSA-17-129-02) Siemens devices using the PROFINET Discovery and Configuration Protocol Original release date: May 09, 2017 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol (DCP) Vulnerability: Denial of Service AFFECTED PRODUCTS Siemens reports that these vulnerabilities affect the following products using PROFINET DCP: SIMATIC CP 343-1 Std, CP 343-1 Lean: All versions, SIMATIC CP 343-1 Adv: All versions, SIMATIC CP 443-1 Std, CP 443-1 Adv: All versions prior to V3.2.17, SIMATIC CP 443-1 OPC-UA: All versions, SIMATIC CP 1243-1: All versions, SIMATIC CM 1542-1: All versions prior to V2.0, SIMATIC CP 1543SP-1, CP 1542SP-1 and CP 1542SP-1 IRC: All versions, SIMATIC CP 1543-1: All versions prior to V2.1, SIMATIC RF650R, RF680R, RF685R: All versions prior to V3.0, SIMATIC CP 1616, CP 1604, DK-16xx PN IO: All versions prior to V2.7, SCALANCE X200: All versions, SCALANCE X200 IRT: All versions, SCALANCE X300, X408, X414: All versions, SCALANCE XM400, XR500: All versions, SCALANCE W700: All versions prior to V6.1, SCALANCE M-800,S615: All versions, Softnet PROFINET IO for PC-based Windows systems: All versions, IE/PB-Link: All versions prior to V3.0, IE/AS-i Link PN IO: All versions, SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced: All versions, SITOP PSU8600 / UPS1600 PROFINET: All versions, SIMATIC ET 200 Interface modules for PROFINET IO: SIMATIC ET 200AL: All versions, SIMATIC ET 200ecoPN: All versions, SIMATIC ET 200M: All versions, SIMATIC ET 200MP: All versions prior to V4.0.1, SIMATIC ET 200pro: All versions, SIMATIC ET 200S: All versions, SIMATIC ET 200SP: All versions, PN/PN Coupler: All versions, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller: All versions prior to V4.1.1 Patch04, EK-ERTEC 200P PN IO: All versions prior to V4.4.0 Patch01, EK-ERTEC 200 PN IO: All versions prior to V4.2.1 Patch03, SIMATIC S7-200 SMART: All versions, SIMATIC S7-300 including F and T: All versions prior to V3.X.14, SIMATIC S7-400 including F and H: All versions, SIMATIC S7-1200 including F: All versions prior to V4.2.1, SIMATIC S7-1500 including F, T, and TF: All versions prior to V2.1, SIMATIC S7-1500 Software Controller including F: All versions prior to V2.1, SIMATIC WinAC RTX 2010 including F: All versions, SIRIUS ACT 3SU1 interface module PROFINET: All versions, SIRIUS Soft starter 3RW44 PN: All versions, SIRIUS Motor starter M200D PROFINET: All versions, SIMOCODE pro V PROFINET : All versions, SINAMICS: SINAMICS DCM: All versions, SINAMICS DCP: All versions, SINAMICS G110M / G120(C/P/D) w. PN: All versions prior to V4.7 SP6 HF3, SINAMICS G130 and G150: All versions prior to V4.8 HF4, SINAMICS S110 w. PN: All versions, SINAMICS S120: All versions prior to V4.8 HF4, SINAMICS S150: All versions prior to V4.8 HF4, SINAMICS V90 w. PN: All versions, SIMOTION: All versions prior to V4.5 HF1, SINUMERIK 828D: V4.5 and prior: All versions, V4.7: All versions prior to V4.7 SP4 HF1, SINUMERIK 840D sl: V4.5 and prior: All versions prior to V4.5 SP6 HF8, V4.7: All versions prior to V4.7 SP4 HF1, and SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels: All versions. IMPACT Successful exploitation of these vulnerabilities could cause the targeted device to enter a denial-of-service condition, which may require human interaction to recover the system. MITIGATION The attacker must have network access to the local Ethernet segment (Layer 2). Siemens strongly recommends verifying that the affected products are protected as described in PROFINET Security Guidelines and Siemens Operational Guidelines in order to run the devices in a protected IT environment. http://www.profibus.com/download/downloads/profinet-security-guideline/display/ (link is external) https://www.siemens.com/cert/operational-guidelines-industrial-security (link is external) Siemens provides firmware updates fixing the vulnerabilities for the following affected products and recommends users update to the new fixed version: SIMATIC CP 443-1 Std: Update to V3.2.17 https://support.industry.siemens.com/cs/ww/en/view/109745387 (link is external) SIMATIC CP 443-1 Adv: Update to V3.2.17 https://support.industry.siemens.com/cs/ww/en/view/109745388 (link is external) SIMATIC CM1542-1: Update to V2.0 https://support.industry.siemens.com/cs/ww/en/view/109744924 (link is external) SIMATIC CP 1543-1: Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109747253 (link is external) SIMATIC RF650R, RF680R, RF685R: Update to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109743740 (link is external) SIMATIC CP 1616, CP 1604, DK-16xx PN IO: Update to V2.7 https://support.industry.siemens.com/cs/ww/en/view/109743058 (link is external) SCALANCE W700: Update to V6.1.0 https://support.industry.siemens.com/cs/ww/en/view/109744953 (link is external) IE/PB-Link: Upgrade to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109744504 (link is external) Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller: All versions prior to V4.1.1 Patch04 EK-ERTEC 200P PN IO: All versions prior to V4.4.0 Patch01 EK-ERTEC 200 PN IO: All versions prior to V4.2.1 Patch03 Updates for Development/Evaluation Kits for PROFINET IO can be obtained via ComDeC at comdec@siemens.com (link sends e-mail) or pic.industry@siemens.com (link sends e-mail) SIMATIC S7-300 including F and T: Update to V3.X.14 https://support.industry.siemens.com/cs/ww/de/ps/13752/dl (link is external) or https://support.industry.siemens.com/cs/ww/en/ps/13752/dl (link is external) SIMATIC S7-1200 including F: Update to V4.2 https://support.industry.siemens.com/cs/ww/en/view/109741461 (link is external) SIMATIC S7-1500 including F, T and TF: Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109478459 (link is external) SIMATIC S7-1500 Software Controller including F: Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109478528 (link is external) SINAMICS: SINAMICS G110M/G120(C/P/D) w. PN: Update to V4.7 SP6 HF3 https://support.industry.siemens.com/cs/ww/en/view/109482659 (link is external) SINAMICS G130 and G150: V4.8: Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109742040 (link is external) SINAMICS S120: V4.8: Update to V4.8 HF4 https://support.industry.siemens.com/cs/de/en/view/109740193 (link is external) SINAMICS S150: V4.8: Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109742040 (link is external) SIMOTION: Update to V4.5 HF1 https://support.industry.siemens.com/cs/ww/en/view/109742328 (link is external) SINUMERIK 828D: V4.7: All versions prior to V4.7 SP4 HF1 SINUMERIK software can be obtained from the local Siemens account manager SINUMERIK 840D sl: V4.5 and prior: Update to V4.5 SP6 HF8 V4.7: Update to V4.7 SP4 HF1 SINUMERIK software can be obtained from the local Siemens account manager Siemens is preparing updates for the remaining affected products and recommends the following mitigations in the meantime: Apply cell protection concept Use VPN for protecting network communication between cells Apply Defense-in-Depth As a general security measure Siemens and PNO strongly recommend protecting industrial control systems networks with appropriate mechanisms. Siemens encourages users to verify that the affected products are protected as described in PNO Security Guidelines and Siemens operational guidelines in order to run the devices in a protected IT environment. https://www.siemens.com/cert/operational-guidelines-industrial-security (link is external) For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-293562 at the following location: http://www.siemens.com/cert/en/cert-security-advisories.htm (link is external) ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. VULNERABILITY OVERVIEW IMPROPER INPUT VALIDATION CWE-20 Specially crafted PROFINET DCP broadcast packets could cause a denial-of-service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. CVE-2017-2680 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). IMPROPER INPUT VALIDATION CWE-20 Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial-of-service condition in that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. CVE-2017-2681 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). RESEARCHER Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team reported these vulnerabilities directly to Siemens. BACKGROUND Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Chemical, Energy, Water and Wastewater Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov (link sends e-mail) Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBWRKulox+lLeg9Ub1AQgfNRAArGw+cQRYaanmDWlp7BR0C00SzgLwT92f 9QLzE8FX3fjK383aA1/JhJ8CYQXC4Ju9SoQER+4YUYdNRltfUiYiQPMjCi4U300H k7tRTdUS82VcazepxZXsQxmOLDGHmTmJiuTjwEt0bub9scKFxpfRlfcawLiVIOqi qC+pQeYjaSCh2yu3oC9Mco93O18Lh/gd/79QpPoWwPfmXyDItcG+sD77QRVnKeZm UgFw3yvZSWgWHtgXPxcsGELhZsLcoggyIn3fFLVxm+4bf47QSKY3UUizQRvgXscL pgFP8QkP7MXiiVo6k1BIG55Uv+vlznrRPbDsfzmS3dlA1rK0VMhjBw6Apy739y3x DgrIf7CYhl0ZOYbYhJCZVpuksqt4mLygnI/kuMtWuj23iBSWzRVIYi8VNJFZUTh3 r6Ss10z0zI0rtxfEDew0YQK/9X/O1ws9rsYSLl6SVTtaD4hPrRPzl01c95jk4cs+ iYFlYuISPCuvti7koL5ESdQqjyTAAWOr1HTVkJicLygR7+QRINCHIgpdvE5hBP5a lVHCGT3DBVMbOhFGAHbxhjws1Y/49RH7t3161xDPOc4JrS83YdtfwcmifyG6zxEs PPG++NAhYXRFo8dE3Pq3YAsZuq5e7F/iHJ6YVzTcbgeuCss6BQ+APWzPMOTWw7m1 XmyjtdETG5I= =wzg4 -----END PGP SIGNATURE-----