Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2017.1932.2 Siemens Molecular Imaging Vulnerabilities 4 August 2017 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens Molecular Imaging Publisher: ICS-CERT Operating System: Windows Impact/Access: Execute Arbitrary Code/Commands -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2015-7861 CVE-2015-7860 CVE-2015-1635 CVE-2015-1497 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSMA-17-215-02 Comment: Exploits that target these vulnerabilities are known to be publicly available. Revision History: August 4 2017: Added CVEs to header information August 4 2017: Initial Release - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSMA-17-215-02) Siemens Molecular Imaging Vulnerabilities Original release date: August 03, 2017 Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. OVERVIEW Siemens has identified four vulnerabilities in Siemens' Molecular Imaging products running on Windows 7. Siemens is preparing updates for the affected products. These vulnerabilities could be exploited remotely. Exploits that target these vulnerabilities are known to be publicly available. AFFECTED PRODUCTS Siemens reports that the vulnerabilities affect the following products: Siemens PET/CT Systems: All Windows 7-based versions, Siemens SPECT/CT Systems: All Windows 7-based versions, Siemens SPECT Systems: All Windows 7-based versions, and Siemens SPECT Workplaces/Symbia.net: All Windows 7-based versions. IMPACT Successful exploitation of these vulnerabilities may allow the attacker to remotely execute arbitrary code. Impact to individual organizations depends on many factors that are unique to each organization. NCCIC/ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment and specific clinical usage. BACKGROUND Siemens is an international company headquartered in Munich, Germany. The affected products, Select Molecular Imaging products, are used in medical imaging. According to Siemens, Molecular Imaging products are deployed across the Healthcare and Public Health sector. Siemens estimates that these products are used worldwide. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') [a] An unauthenticated remote attacker could execute arbitrary code by sending specially crafted HTTP requests to the Microsoft web server (Port 80/TCP and Port 443/TCP) of affected devices. CVE-2015-1635[b] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).[c] IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION')[d] An unauthenticated remote attacker could execute arbitrary code by sending a specially crafted request to the HP Client automation service on Port 3465/TCP of affected devices. CVE-2015-1497[e] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).[f] IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER[g] An unauthenticated remote attacker could execute arbitrary code by sending a specially crafted request to the HP Client automation service of affected devices. CVE-2015-7860[h] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).[i] PERMISSIONS, PRIVILEGES, AND ACCESS CONTROLS[j] An unauthenticated remote attacker could execute arbitrary code by sending a specially crafted request to the HP Client automation service of affected devices. CVE-2015-7861[k] has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).[l] VULNERABILITY DETAILS EXPLOITABILITY These vulnerabilities could be exploited remotely. EXISTENCE OF EXPLOIT Exploits that target these vulnerabilities are publicly available. DIFFICULTY An attacker with a low skill would be able to exploit these vulnerabilities. MITIGATION Siemens is preparing updates for the affected products and recommends protecting network access to the Molecular Imaging products with appropriate mechanisms. It is advised to run the devices in a dedicated network segment and protected IT environment. If this is not possible, Siemens recommends the following: If patient safety and treatment is not at risk, disconnect the product from the network and use in standalone mode. Reconnect the product only after the provided patch or remediation is installed on the system. Siemens is able to patch systems capable of Remote Update Handling (RUH) much faster by remote software distribution compared to onsite visits. Therefore users of RUH-capable equipment are recommended to clarify the situation concerning patch availability and remaining risk in the local customer network with the Siemens Customer Care Center first and then to reconnect the systems in order to receive patches as quickly as possible via RUH. This ensures smooth and fast receipt of updates and therefore supports reestablishment of system operations. In addition, Siemens recommends: Ensure users have appropriate backups and system restoration procedures. For specific patch and remediation guidance information contact a local Siemens customer service engineer or a Siemens regional support center. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-814457 at the following location: http://www.siemens.com/cert/advisories ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all medical devices and/or systems, and ensure that they are not accessible from the Internet. Locate all medical devices and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. ICS-CERT also provides a section for security recommended practices on the ICS-CERT web page at http://ics-cert.us-cert.gov/content/recommended-practices. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Additional mitigation guidance and recommended practices are publicly available in the ICS-CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site (http://ics-cert.us-cert.gov/). Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. a. CWE-94: Improper Control of Generation of Code ('Code Injection'), https://cwe.mitre.org/data/definitions/94.html, web site last accessed August 03, 2017. b. NVD, https://nvd.nist.gov/vuln/detail/CVE-2015-1635, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. c. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed August 03, 2017. d. CWE-94: Improper Control of Generation of Code ('Code Injection'), https://cwe.mitre.org/data/definitions/94.html, web site last accessed August 03, 2017. e. NVD, https://nvd.nist.gov/vuln/detail/CVE-2015-1497, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. f. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed August 03, 2017. g. CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer, https://cwe.mitre.org/data/definitions/119.html, web site last accessed August 03, 2017. h. NVD, https://nvd.nist.gov/vuln/detail/CVE-2015-7860, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. i. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed August 03, 2017. j. CWE-264: Permissions, Privileges, and Access Controls, https://cwe.mitre.org/data/definitions/264.html, web site last accessed August 03, 2017. k. NVD, https://nvd.nist.gov/vuln/detail/CVE-2015-7861, NIST uses this advisory to create the CVE web site report. This web site will be active sometime after publication of this advisory. l. CVSS Calculator, https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S..., web site last accessed August 03, 2017. Contact Information For any questions related to this report, please contact ICS-CERT at: Email: ics-cert@hq.dhs.gov Toll Free: 1-877-776-7585 International Callers: (208) 526-0900 For industrial control systems security information and incident reporting: http://ics-cert.us-cert.gov ICS-CERT continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: http://www.auscert.org.au/render.html?cid=1980 =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBWYPI9Ix+lLeg9Ub1AQjOrg/+KJ7m7p9XCHu5BXRHLT1azKXnhqQiJd4S 4qU+zohE8b2ChNYiM7TKj15EDGtcdqwH1Tjw75SlHlgQVIBdA9lffdDHCrmrNL29 Q0uuQXdbrDf/8rQV4A1a07d5V3rc6ewW728Qzs5E3O/gVsd4sIYJogB8erHFmbns SW3gXO6meKoQv+Tx0zOrCPGr1Audi6Cmr2Sc7TYrSsbXUlwmyZkmzMCOezORTuE1 Kun+L3vzT+V8f8xKNyufNWDKX/FGn88xMoL6inOyX5NHVOq0CM5sV7Q3zW0vtWEF tWG2TRVtx86tfU/VQGWjV8rQpjN+78ZFsIE9BFROAF8ov9h0EIj8WGqUxz6ObwQf w/yL6yoH5soWdbPCtgVbohga9a3+kmBK66nlR34uT5RIs+HWF96OPlcTZ9pfaNy9 xMLy/Mhz0Sr9+HRyhemvQKMzMcVm6OXkA4T01vCv5FJC91hde2kjY611zRm3PCPe PfbCfoUgn2ZZAMjuhmotT6Kkw2VrJMU7qKHZ1pWLVuvP2/G+PmdZL4aslx+F03oY UMDi3VxZLt3kDlHYQFK/CSMLONCTz/SnA2Ha9P3PrmrvU0ntY38K03z6JoIye4EN 8TThx+8V5Q0LreOUrxeBX375Lb8UEyXeJZx03UQdh3AHZmjtkEuCLm/CPJVrElc8 pnXe9M3CYlc= =y9qC -----END PGP SIGNATURE-----