Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.2736 Advisory (icsa-22-153-02) Illumina Local Run Manager 3 June 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Local Run Manager (LRM) Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-1524 CVE-2022-1521 CVE-2022-1519 CVE-2022-1518 CVE-2022-1517 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-153-02 Comment: CVSS (Max): 10.0 CVE-2022-1517 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-153-02) Illumina Local Run Manager Original release date: June 02, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 10.0 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Illumina o Equipment: Local Run Manager (LRM) o Vulnerabilities: Path Traversal, Unrestricted Upload of File with Dangerous Type, Improper Access Control, Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow an unauthenticated malicious actor to take control of the affected product remotely and take any action at the operating system level. An attacker could impact settings, configurations, software, or data on the affected product and interact through the affected product with the connected network.. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following devices and instruments using LRM software are affected: Illumina In Vitro Diagnostic (IVD) devices: o NextSeq 550Dx: LRM Versions 1.3 to 3.1 o MiSeq Dx: LRM Versions 1.3 to 3.1 Researcher Use Only (ROU) instruments: o NextSeq 500 Instrument: LRM Versions 1.3 to 3.1 o NextSeq 550 Instrument: LRM Versions 1.3 to 3.1 o MiSeq Instrument: LRM Versions 1.3 to 3.1 o iSeq 100 Instrument: LRM Versions 1.3 to 3.1 o MiniSeq Instrument: LRM Versions 1.3 to 3.1 3.2 VULNERABILITY OVERVIEW 3.2.1 EXECUTION WITH UNNECESSARY PRIVILEGES CWE-250 LRM utilizes elevated privileges. An unauthenticated malicious actor can upload and execute code remotely at the operating system level, which can allow an attacker to change settings, configurations, software, or access sensitive data on the affected produc. An attacker could also exploit this vulnerability to access APIs not intended for general use and interact through the network.. CVE-2022-1517 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/ C:H/I:H/A:H ). 3.2.2 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22 LRM contains a directory traversal vulnerability that can allow a malicious actor to upload outside the intended directory structure. CVE-2022-1518 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/ C:H/I:H/A:H ). 3.2.3 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434 LRM does not restrict the types of files that can be uploaded to the affected product. A malicious actor can upload any file type, including executable code that allows for a remote code exploit.. CVE-2022-1519 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:C/ C:H/I:H/A:H ). 3.2.4 IMPROPER ACCESS CONTROL CWE-284 LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data. CVE-2022-1521 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:N/S:U/ C:H/I:H/A:N ). 3.2.5 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319 LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials.. CVE-2022-1524 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is ( AV:N/AC:H/PR:N/UI:N/S:U/ C:H/I:H/A:N ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Pentest, Ltd., (pentest.co.uk) reported these vulnerabilities to Illumina. Illumina reported these vulnerabilities to CISA. 4. MITIGATIONS Illumina has developed a software patch to protect against the remote exploitation of these vulnerabilities and is actively working to provide a permanent software fix for current and future instruments. For instruments connected to the Internet, the software patch is available for download . For affected products not connected to the Internet, Illumina has developed other options for the installation of the software patch. Please contact Illumina Tech Support at techsupport@illumina.com to obtain information about these options. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov/ics in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBYpllAMkNZI30y1K9AQjteRAAgztXRTWQOEUig8/rxwyXpu/m/IG5016e o08tolXsNaHi1P78+JcFBVsWQx13qIcRzp8ZuHMaAll1wk3ftIIEAvbR99ONKs1C 05UELnjWgiXDO1ZGcJDj8CLN3VSGexXbY8I6YDAKjaNVDjNdxZ2MWqn0eeAeUPF1 jMDHRUDS38h2TV/b1ebcnSqUnayspxQBDUVJ+VzDuMbbVjMTRWozDCvazDMIarmh stJwb79y1nx7CkhI/qHg6DjaLb/pyEyB8U4pjFT9u6Hlx6Q93L+lMCHs1Blk975k rAZwc3bSGw7B9gCHXdn6C5yKgkrsscLXiIwGlgXi0B6oUbAdRS0g1/z3/SIW0k2i 1DaPGjEI8PUMBzLQRLEq7nhWL//eQU4V+tqXBBmRMcDm9Ri0fGxS/YQJL86I84OF B0jxaRV9+wYhRcmKfLdgWnrRJ2rEGQ9Ub/Z7uUM22JCcKE0eWtR/+Ilx31Xrm+J2 kj/aUhXCpiIQgaCxnZKWcIA3fvmBzT1tTD26MGne3riZOYgOCv8DJ+RLBLoASyWk dk8kn7pRqOGlAP56vlRfQqeiIjkNlcZnXREXwHNwV9DPB45o/+ptAUQSQJU0B+w7 7IYb6dyWZw6x4p5NaM5w5AZHzAENzjoNl8VjLYqjziXC6NiAsdW1R7Op+G0qaLRm WWQL6g3qNk8= =EFac -----END PGP SIGNATURE-----