Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.4034 Advisory (icsa-22-223-05) Siemens SICAM A8000 Web Server Module 12 August 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens SICAM A8000 Web Server Module Publisher: ICS-CERT Operating System: Network Appliance Resolution: Mitigation CVE Names: CVE-2021-46304 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-223-05 Comment: CVSS (Max): 4.3 CVE-2021-46304 (CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N) CVSS Source: ICS-CERT Calculator https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-223-05) Siemens SICAM A8000 Web Server Module Original release date: August 11, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 4.3 o ATTENTION: Exploitable remotely/low attack complexity o Vendor: Siemens o Equipment: SICAM A8000 CP-8000, CP-8021, CP-8022 o Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthenticated access to the web interface of the affected web server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens has reported that this vulnerability affects the following SICAM A8000 Web Server Module products and versions: o CP-8000 MASTER MODULE WITH I/O -25/+70C (6MF2101-0AB10-0AA0): All Versions o CP-8000 MASTER MODULE WITH I/O -40/+70C (6MF2101-1AB10-0AA0): All Versions o CP-8021 MASTER MODULE (6MF2802-1AA00): All Versions o CP-8022 MASTER MODULE WITH GPRS (6MF2802-2AA00): All Versions The affected protocol firmware utilized with the web server modules includes the following: o AGPMT0 (AGP Master) o DNPiT1 (DNP3 TCP/IP Server) o DNPiT2 (DNP3 TCP/IP Client) o DNPMT0 (DNP3 Master seriell) o DNPST0 (DNP3 Slave seriell) o ET83 (61850 Ed.1) o ET85 (61850 Ed.2) o MBCiT0 (MODBUS TCP/IP Client) o MBSiT0 (MODBUS TCP/IP Server) o MODMT2 (MODBUS Master seriell) o OPUPT0 (OPCUA Pub/Sub) o OPUPT1 (Mindconnect) 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER ACCESS CONTROL - CWE-284 The vulnerability could allow attackers to activate a web server module, allowing unauthorized access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems. CVE-2021-46304 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is ( AV:N/AC:L/PR:N/UI:R/S:U/C:L/ I:N/A:N ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Energy o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER CybExer Technologies reported this vulnerability to Siemens. 4. MITIGATIONS Siemens provided the following updates to the vulnerabilities for the following products affected: o CP-8000 MASTER MODULE WITH I/O -25/+70C (6MF2101-0AB10-0AA0): There is currently no fix available o CP-8000 MASTER MODULE WITH I/O -40/+70C (6MF2101-1AB10-0AA0): There is currently no fix available o CP-8021 MASTER MODULE (6MF2802-1AA00): There is currently no fix available o CP-8022 MASTER MODULE WITH GPRS (6MF2802-2AA00): There is currently no fix available Siemens has identified the following workarounds and mitigations for users to reduce risk: o Operate the affected web server module only when required and apply the security instructions provided in the updated manual. Siemens recommends users apply General Security Recommendations . As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to the Siemens operational guidelines for industrial security and follow the recommendations in the product manuals. For additional information, please refer to Siemens Security Advisory SSA-185638 . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target these vulnerabilities. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBYvW3O8kNZI30y1K9AQhZfg/5AfBo07DWQs0NZbG9r7feswhkqwKAFeGa RcJf68bFPkYmE64bS/+ax2gtrvCEDeeqrShAO1mZQG329OLooOevwQZepE61zhGY OjdquP32jU7igUIBgyVbkBJ6YaZ0sjHxI0XCvOMMOcViubOAGfKeb7N9Xw2znA91 759GF17jcLoMURBKlsckAaeucBNb/S8MMYTtzrxzS/X8OPqxnGpV3jvhAHzkqlQY 3PehhUVQwcCeuHVXXNbgZvvT1c0dyX3aY27GnIivtCnVVzQ7KtOXzSFrWizRdLq8 g7+O6diCkDXvW47ugOE4G07UbC3/a+jxK/W6hPvvWxINOAPlygTvsRrzqirAUynr ilLQNQhuA5OC3cpegjUu2K78O1HZ8aVsDkiog96LXcqxP6/5Bkim4rH7kQO4uU1g rbTWWWdt2xUUhoAGS8JmfkuOZHW8/0OAlnawJTiN0qVUtaOBkUNBaUcCGRhEMZxV aiE6AfA0AHQ6uS828eZyRfk21vfc0KXWDT2oeMvza4zI3VZmFctxEREwQuFx64Gi wJFao/H7PX7NQ7l+VFBArnMPKEmh/5DdUHWc3M0YUFPO4BFHmZzeW+4F7YkgVxKz rPESsKkiU3G4Ha1fxCez/4EJ4I8qph/XVPj7yDQo3xm7Mtjgd2AfYwEvWrCB4M1p jQj48RcTBFo= =aHU4 -----END PGP SIGNATURE-----