Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.4035 Advisory (icsa-22-223-04) Emerson ROC800, ROC800L and DL8000 12 August 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Emerson ROC800 Emerson ROC800L Emerson DL8000 Publisher: ICS-CERT Operating System: Network Appliance Resolution: Mitigation CVE Names: CVE-2022-30264 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-22-223-04 Comment: CVSS (Max): 6.3 CVE-2022-30264 (CVSS:3.0/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-22-223-04) Emerson ROC800, ROC800L and DL8000 Original release date: August 11, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.3 o ATTENTION: High attack complexity o Vendor: Emerson o Equipment: ROC800, ROC800L and DL8000 o Vulnerability: Insufficient Verification of Data Authenticity CISA is aware of a public report, known as "OT:ICEFALL" that details vulnerabilities found in multiple operational technology (OT) vendors. CISA is issuing this advisory to provide notice of the reported vulnerabilities and identify baseline mitigations for reducing risks to these and other cybersecurity attacks. 2. RISK EVALUATION Successful exploitation of this vulnerability could cause file manipulation. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ROC800, a remote automation controller, are affected: o ROC800: All versions o ROC800L: All versions o DL8000: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 INSUFFICIENT VERIFICATION OF DATA AUTHENTICITY CWE-345 The affected product uses the ROC protocol for communications, which could allow an attacker to read, write and delete file or folder operations. CVE-2022-30264 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is ( AV:L/AC:H/PR:H/UI:R/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Multiple Sectors o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Daniel dos Santos and Jos Wetzels from Forescout Technologies reported this vulnerability to CISA. 4. MITIGATIONS Emerson recommends users follow the guidance given in the ROC800-Series Remote Operations Controller Instruction Manual under section 1.11 Secure Gateway D301766X012 CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBYvW4EMkNZI30y1K9AQhTOQ//WlGs/JC6YJAjPnZlhRpdkd4/I7bWi3SQ t+s5/KgsV0b0sZmpQZiM29f+8ExoWhfcPGbvGjYk5KEIMZ0aQwi83bSmbOsrl9uV yhSItVduZ55R6KKHsHOHwTYAIVSPsheHCqiykw6oOnU6d30r344yZBMsO/3v8wW9 wPHTyxY66zWD1dekNUxoreDkhkO7P90vQADIiLt03eimrL6Klgamch/XKH6mWJSS /r6jK+HpvXe9ZJDn5hJsEU4uSQBDwbgl1HES7J/758u46GJmWUXojUCzSC/3GRJj S6nd5mIJHasbbWI9ow5D11pQum2NNQ+8Q9T5GTeu9PcMLM79rAoC1nSGhazXXXHW 48S/CVz7LEv/Zs2fMD4g5pezQgtxLVGrwrKEFzaFDivvM60BGXUivkBpYy4uXg// O0xLfKeGPKoczN5WL/cHVe0o+q5UaVMipqSwI5lYKTDUf9dDmYHX//xL+K8s76p/ tsR8sOXRel+qNP+4Jp5rWODTD+ye6Sleok/gEEjeghyXspembwKz2bcrQbN2SFuL bP2w1rllZ6OWXFHpBRYTOtQL1hWQHUDPQHaqJl00gtlSwgUaYQ2YuB7PAH5Zab/m hp3tPXmGGbZQChGIA5o5Pin9QWnoKjvMG/0heAnNDAXALqlf3Ab0wWrPmYMyehwp +Q44R3c8Eyg= =+k8K -----END PGP SIGNATURE-----