Protect yourself against future threats.
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2022.6280 Advisory (icsma-22-335-01) BD BodyGuard Pumps 2 December 2022 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: BD BodyGuard Pumps Publisher: ICS-CERT Operating System: Network Appliance Resolution: Patch/Upgrade CVE Names: CVE-2022-43557 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsma-22-335-01 Comment: CVSS (Max): 5.3 CVE-2022-43557 (CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H) CVSS Source: ICS-CERT Calculator: https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Medical Advisory (ICSMA-22-335-01) BD BodyGuard Pumps Original release date: December 01, 2022 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 5.3 o Vendor: Becton, Dickinson and Company (BD) o Equipment: BodyGuard Pumps o Vulnerability: Missing Protection Mechanism for Alternate Hardware Interface 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to change configuration settings or disable the pump. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following BD BodyGuard products are affected: o BD BodyGuard o CME BodyGuard 323 (2nd Edition) o CME BodyGuard 323 Color Vision (2nd Edition) o CME BodyGuard 323 Color Vision (3rd Edition) o CME BodyGuard Twins (2nd Edition) 3.2 VULNERABILITY OVERVIEW 3.2.1 MISSING PROTECTION MECHANISM FOR ALTERNATE HARDWARE INTERFACE CWE-1299 The affected BD BodyGuard infusion pumps allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access and specialized equipment and knowledge could configure or disable the pump. No electronic protected health information (ePHI), protected health information (PHI), or personally identifiable information (PII) is stored in the pump. CVE-2022-43557 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is ( AV:P/AC:H/PR:N/UI:N/S:U/ C:L/I:L/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Healthcare and Public Health o COUNTRIES/AREAS DEPLOYED: Deployed outside the U.S o COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER BD reported this vulnerability to CISA. 4. MITIGATIONS BD recommends the following mitigations to reduce risk associated with this vulnerability: o Ensure physical access controls are in place to ensure only authorized users have access to the affected product. o Ensure only BD-approved equipment is connected to the RS-232 interface of the affected pumps. o When the affected pumps are delivering infusions, ensure no equipment is connected to the RS-232 interface. o Protect connected computer systems with BodyComm software with standard security measures. For additional information, users should see BD's security bulletin . CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet . o Locate control system networks and remote devices behind firewalls and isolate them from business networks. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: https://auscert.org.au/gpg-key/ iQIVAwUBY4lpgckNZI30y1K9AQjuuQ/8DMAO1mI+v/TGgmNERGc3cOPPtlPjgiR5 DV8CjELPqfBdlQCLkvfomDXAquvGEESHX3TLPy5hz1w++Moig3WSxFhP48MnmC0A vbINXhjaoH5XDsPnr/yg5b8jBQhZa9YNYGJracv6mkoCKR+XzpEkKv6rtg1hvgoQ JVD3pV2PzsGB5rklI0gcrQ6o/wSU8p1joDC8TYrX8ZgmLdaQGAp1WHsv0G5Q2Ih2 rMw4wI7Nkvy+oH6FSotsRe3pKqXSuNQb9jxRj/jfz0L/bAD+8uaA54iwlUNPsz31 SSYQWAtX9SZ+982CC4JEc2IlwXvnhbY5oab6aXuH2Ultz6d9lL2Gz7h9B5WjEU0X iCdfrRYjqkSqBT4BnJ8hn3lfZN020CSKlJyf+xdsIZ1nMp7GVbCRyymhkpGYHLDx tO0a+bK3agTdOIu0iHHp3qvwbIsezy02HVLiffiqmUUgXZ+KGxBnkfYTfYAtyrnU EjIEdgpcggEbJXV8c1bIqiTKIZHYiMt634vrQ8XdTlyH0ODGPfGU6PuoIGNWe/0/ 7kKi08E73wowbnn4EfxpPFkEsPhfIBpLXsMQrER1ApZzI6lXVdvi9P2/Df9jZ3v2 8d+2nDYttSYrMLtGhH+M4L7fZSaV+6Xwrc2jg6kQdyfCumCN1GOII/wvdIFUP7rn zAd6Hf5JxfI= =pYTn -----END PGP SIGNATURE-----