-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2018.2388 Advisory (ICSA-18-226-02) Siemens OpenSSL Vulnerability in Industrial Products 16 August 2018 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Siemens MindConnect Siemens SIMATIC Siemens SINUMERIK Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Access Confidential Data -- Remote/Unauthenticated Resolution: Patch/Upgrade CVE Names: CVE-2017-3737 Original Bulletin: https://ics-cert.us-cert.gov/advisories/ICSA-18-226-02 - --------------------------BEGIN INCLUDED TEXT-------------------- Advisory (ICSA-18-226-02) Siemens OpenSSL Vulnerability in Industrial Products Legal Notice All information products included in http://ics-cert.us-cert.gov are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see http://www.us-cert.gov/tlp/. 1. EXECUTIVE SUMMARY o CVSS v3 5.9 o ATTENTION: Exploitable remotely o Vendor: Siemens o Equipment: Industrial Products o Vulnerability: Cleartext Transmission of Sensitive Information 2. RISK EVALUATION Successful exploitation of this vulnerability could result in unencrypted data being transmitted by the SSL/TLS record layer. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following industrial products: o MindConnect IoT2040: All versions prior to v03.01, o MindConnect Nano (IPC227D): All versions prior to v03.01, o SIMATIC ET 200SP Open Controller CPU 1515SP PC (OC1): All versions prior to v2.1, o SIMATIC HMI WinCC Flexible: All versions, o SIMATIC IPC DiagBase: All versions, o SIMATIC IPC DiagMonitor: All versions, o SIMATIC S7-1200: All versions, o SIMATIC S7-1500: All versions prior to v2.5.2, o SIMATIC S7-1500 Software Controller: All versions, o SIMATIC STEP 7 (TIA Portal): All versions prior to v15 Update 2, o SIMATIC WinCC (TIA Portal): All versions prior to v15 Update 2, o SIMATIC WinCC OA v3.14: All versions, o SIMATIC WinCC OA v3.15: All versions, o SIMATIC WinCC OA v3.16: All versions, o SINUMERIK Integrate Access MyMachine service engineer client as part of Sinumerik Integrate Product suite: All versions prior to and including v4.1.7, and o SINUMERIK Integrate Operate Client as part of Sinumerik Integrate Product suite: All versions prior to and including v2.0.11 / v3.0.11 3.2 VULNERABILITY OVERVIEW 3.2.1 CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319 In OpenSSL 1.0.2 an "error state" mechanism was introduced. This "error state" mechanism does not work correctly if SSL_read() or SSL_write() is called directly by an application. This could result in data being sent out unencrypted by the SSL/TLS record layer. Successful exploitation requires an attacker to cause a fatal error in the targeted SSL/TLS handshake algorithm, and that the targeted application calls SSL_read() or SSL_write() only after receiving the fatal error. No user interaction or privileges are required to exploit this security vulnerability. The vulnerability could allow a compromise of data confidentiality by transmitting it unencrypted over the network. CVE-2017-3737 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/ I:N/A:N). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Germany 3.4 RESEARCHER Siemens reported this vulnerability to NCCIC. 4. MITIGATIONS Siemens has provided updates for the following products to fix the vulnerability: o MindConnect IoT2040: Install v03.01 or newer via Mindsphere web front-end o MindConnect Nano (IPC227D): Install v03.01 or newer via Mindsphere web front-end o SIMATIC S7-1500: Update to v2.5.2 https://support.industry.siemens.com/cs/ww/en/view/109478459 SIMATIC STEP 7 and WinCC (TIA Portal): Update to v15 Update 2 or newer https://support.industry.siemens.com/cs/ww/en/view/109755826 o SINUMERIK Integrate Access MyMachine service engineer client as part of Sinumerik Integrate Product suite: Update to v4.1.8 o SINUMERIK Integrate Operate Client as part of Sinumerik Integrate Product suite: Update to v2.0.12 / v3.0.12 Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: o S7-1200: Disable web server within the device configuration if it is not used, or limit access to the web server on a particular Ethernet/PROFINET port/interface if possible (setting is under General /Web server access). As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/ operational-guidelines-industrial-security), following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity For more information on this vulnerability and associated software updates, please see Siemens security advisory SSA-179516 on their website: https://www.siemens.com/cert/advisories NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. o Locate control system networks and remote devices behind firewalls, and isolate them from the business network. o When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices. NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. High skill level is needed to exploit. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBW3Uo22aOgq3Tt24GAQg0jhAApVRjPXLb2VSTEI89Lr+JN5knweI73G8B AbagqTiZL5AStiCMYnLGSoqNZqHVjuui8KvGSghfwFJZbOd/bZtq2gk4HBiUc0Li Z4vB2upGcBDl7vTuiu1R21Q2j3MeKGQUT77X4MZkKgHBYzSrdFR8zwgUtX4X72cz vNdYRmOsiybH3c7+CAYfT0xdd6Op8JWVks2p5ZnDkhy3MkGdEcgCnBiuHPIYIYmR TI8trnCTcnC3bRWSF11za/k93h23BJL65S/dHkXKFgOMWMnyIQZlps8YNCjk98Pk sBTQvtk3ZwowVakiZE7vt7EtTpCzj6uIOzpgWx1B3qeN+IcAoQfArUEC+fLzRK+N 4FbFDrI1DN9csdNb2o2MoNCLbBt6FTHO570ix7KeywCrQL4K1Hs2C+89fv+nwGsL ps3fYFVqQ1wvRc0LVPIbVu9iE0oKKlbyFqy5h+hk0CxSixT5Rcg+RoqnwjyVbKdc XpuXRT96zogO8g2BjjTrk1slvUVGiseujb4PcUSjvM6OgfuGXn3P0kEgEPA1Pc4w 2+KJs/nR+aKiWPplH+i+NJLIXI7RV0jfYJUuPKQ0yde4QiU6DTtjfQyWcXsWLn6s OVqwtEE537zacWe5AfecN2bprlUm8Z8IyKtmz+4ROWO5EmDQYwMmndXQyaFKjX4R 9RLEOwqmP/E= =Jc3a -----END PGP SIGNATURE-----