-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 =========================================================================== AUSCERT External Security Bulletin Redistribution ESB-2021.4098 Advisory (icsa-21-336-07) Hitachi Energy PCM600 Update Manager 3 December 2021 =========================================================================== AusCERT Security Bulletin Summary --------------------------------- Product: Hitachi Energy PCM600 Update Manager Publisher: ICS-CERT Operating System: Network Appliance Impact/Access: Reduced Security -- Existing Account Resolution: Patch/Upgrade CVE Names: CVE-2021-22278 Original Bulletin: https://us-cert.cisa.gov/ics/advisories/icsa-21-336-07 - --------------------------BEGIN INCLUDED TEXT-------------------- ICS Advisory (ICSA-21-336-07) Hitachi Energy PCM600 Update Manager Original release date: December 02, 2021 Legal Notice All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/ . 1. EXECUTIVE SUMMARY o CVSS v3 6.7 o Vendor: Hitachi Energy o Equipment: PCM600 Update Manager o Vulnerability: Improper Certificate Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to bypass the certificate validation and install an untrusted software package. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of PCM600 Update Manager, an update manager for the PCM600 software (a protection and control IED manager), are affected: o PCM600 Update Manager: Versions 2.1, 2.1.0.4, 2.2, 2.2.0.1, 2.2.0.2, 2.2.0.23, 2.3.0.60, 2.4.20041.1, and 2.4.20119.2 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER CERTIFICATE VALIDATION CWE-295 This vulnerability exists due to a logic error in the certificate validation in the affected product. An attacker with administrator rights could exploit this vulnerability by creating software packages and signing those packages with specially crafted certificates, thereby pointing the PCM600 update server location to a different location. The validation flaw causes untrusted software packages to be installed using PCM600 Update Manager. CVE-2021-22278 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is ( AV:L/AC:H/PR:L/UI:R/S:U/ C:H/I:H/A:H ). 3.3 BACKGROUND o CRITICAL INFRASTRUCTURE SECTORS: Energy o COUNTRIES/AREAS DEPLOYED: Worldwide o COMPANY HEADQUARTERS LOCATION: Switzerland 3.4 RESEARCHER A Department of Energy CyTRICS researcher from Idaho National Laboratory reported this vulnerability to Hitachi Energy. 4. MITIGATIONS Hitachi Energy recommends updating the PCM600 Update Manager to Update Manager v2.4.21218.1. This can be done by checking directly on the recommended updates in the PCM600 Update Manager or by downloading it from the Hitachi Energy website . Please see Hitachi Energy advisory 8DBD000056 for additional mitigation and update information. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: o Ensure the least-privilege user principle is followed. o Do not click web links or open unsolicited attachments in email messages. o Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. o Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov . Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents. No known public exploits specifically target this vulnerability. This vulnerability has a high attack complexity. This vulnerability is not exploitable remotely. For any questions related to this report, please contact the CISA at: Email: CISAservicedesk@cisa.dhs.gov Toll Free: 1-888-282-0870 CISA continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product. - --------------------------END INCLUDED TEXT-------------------- You have received this e-mail bulletin as a result of your organisation's registration with AusCERT. The mailing list you are subscribed to is maintained within your organisation, so if you do not wish to continue receiving these bulletins you should contact your local IT manager. If you do not know who that is, please send an email to auscert@auscert.org.au and we will forward your request to the appropriate person. NOTE: Third Party Rights This security bulletin is provided as a service to AusCERT's members. As AusCERT did not write the document quoted above, AusCERT has had no control over its content. The decision to follow or act on information or advice contained in this security bulletin is the responsibility of each user or organisation, and should be considered in accordance with your organisation's site policies and procedures. AusCERT takes no responsibility for consequences which may arise from following or acting on information or advice contained in this security bulletin. NOTE: This is only the original release of the security bulletin. It may not be updated when updates to the original are made. If downloading at a later date, it is recommended that the bulletin is retrieved directly from the author's website to ensure that the information is still current. Contact information for the authors of the original document is included in the Security Bulletin above. If you have any questions or need further information, please contact them directly. Previous advisories and external security bulletins can be retrieved from: https://www.auscert.org.au/bulletins/ =========================================================================== Australian Computer Emergency Response Team The University of Queensland Brisbane Qld 4072 Internet Email: auscert@auscert.org.au Facsimile: (07) 3365 7031 Telephone: (07) 3365 4417 (International: +61 7 3365 4417) AusCERT personnel answer during Queensland business hours which are GMT+10:00 (AEST). On call after hours for member emergencies only. =========================================================================== -----BEGIN PGP SIGNATURE----- Comment: http://www.auscert.org.au/render.html?it=1967 iQIVAwUBYal5CeNLKJtyKPYoAQhkzRAAhbkGp8fFD7c7y9kPiyLNRKGRhLZSWW+h GNo0k7CWgxupF1AwVoDT0AxWNMYWVQ08JrW5keMfcYvk+Ok1t4d270BYkxmpY4nK wVVdF7a28aOR9Tg7QHvel/vlm896wxqHR2fWUi3eVRxYKs3W9t3GuK7BE2Ees1HH tXn/xDFhEAijmRAgfODx8WioT9XeGQzNjeaAV8YVmmNfm9B5rhA7L0kyRUVNBitY wteRQMW4W6i/1YuMmD746z756Gzf/APPxKNjR/bOTE/YdMLXkGQ8HwMIW8n9FD8v iTdvN+F2Z9vyppnid+KhOFV/28KU82atzj7YU94TqOt4+Jc7MiShxCXLhkM03Ghc PGo/C4r+5mpYUtZjDNfDN4cngfyBmP8rJlAzp8xdFRXPPWf+k5hBw2FfeZGCWugx EaZTBsrL8VyIuNlnCmwILZcywnxwNoJhW+D9ncNqo9+mbb9a1rkMn6R7QBDE9Etj kiIe0uKmMCSPdU+5MJHk1IdoxNZB81C2dKXJK23cTkGI119g9osTgd0N7pqzzh3R TcMResLfU8JjDjMWalhFD7YbhEUpZL5vOzg1NiIy0iQk3N2zpR+N51YjRhWuUoV9 KKJU3hXDjIP1T1LCZV4Lg7jhzwYBjwM6cVwNAlUp7Iga8YuurcWSNOhwNrb4H646 8qOHJsrwHaY= =hR7n -----END PGP SIGNATURE-----